Liebert CRV, Row-based Cooling Unit
A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features the iCOM Control and a digital scroll compressor, for high reliability and optimized data center heat management.
- Description
Description
A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features the iCOM Control and a digital scroll compressor, for high reliability and optimized data center heat management.
Best Suited For:
- Banking, Financial and Insurance
- Broadcast and Entertainment
- Data Center/Colocation/Hosting
- Education
- Government
- Telecom
Benefits:
Flexibility
- Horizontal airflow cooling design is suitable for non-raised or raised floors
- Air, water, glycol and chilled water systems available
- Adjustable airflow baffles maximize cooling to rack equipment, allowing the system to be positioned within the row or at the end of the row
- Caster mounted for easy placement
- Multiple units communicate with each other to improve system performance and reduce energy consumption
- Up to 10 racks per cooling unit may be monitored to improve system performance and report rack temperatures
- The iCOM large graphic display allows easy navigation and clear data display
Availability
- Self-adapts to changing conditions to provide 24/7 precision environmental control: cooling, humidity control and air filtration
- Liebert iCOMTM Control provides alerts for preventive maintenance before issues occur
- Variable capacity scroll compressor adapts to load and eliminates compressor cycling, greatly increasing compressor life
Lowest Total Cost of Ownership
- Designed for higher return air temperature to maximize cooling capacity
- Only front and back access required, resulting in minimized installation and service time
- Variable capacity scroll compressor and variable speed EC fans operate efficiently to reduce energy consumption
Ideally Suited For
- Small to medium-sized data centers cold/hot aisle configurations
- Heat density up to 10 kW/rack without containment
- Raised and non-raised floors
- Rooms with a low ceiling where air cannot be ducted
- Spot cooling in large data centers
Features:
- Features variable speed EC plug fans and variable capacity scroll compressor
- Enlarged range available from 10 to 60 kW
- Efficient operation with the iCOMTM Control. The large graphic display allows easy navigation and clear data display
- Includes a 300 mm space saving frame
- Thermal management and humidity control
- Installs within the row of racks
- Low energy consumption