Liebert CRV, Row-based Cooling Unit

A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features the iCOM Control and a digital scroll compressor, for high reliability and optimized data center heat management.​​​​​

Category:
  • Description

Description

A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features the iCOM Control and a digital scroll compressor, for high reliability and optimized data center heat management.​​​​​

Best Suited For:

  • Banking, Financial and Insurance
  • Broadcast and Entertainment
  • Data Center/Colocation/Hosting
  • Education
  • Government
  • Telecom

Benefits:

Flexibility

  • Horizontal airflow cooling design is suitable for non-raised or raised floors
  • Air, water, glycol and chilled water systems available
  • Adjustable airflow baffles maximize cooling to rack equipment, allowing the system to be positioned within the row or at the end of the row
  • Caster mounted for easy placement
  • Multiple units communicate with each other to improve system performance and reduce energy consumption
  • Up to 10 racks per cooling unit may be monitored to improve system performance and report rack temperatures
  • The iCOM large graphic display allows easy navigation and clear data display
Availability
  • Self-adapts to changing conditions to provide 24/7 precision environmental control: cooling, humidity control and air filtration
  • Liebert iCOMTM Control provides alerts for preventive maintenance before issues occur
  • Variable capacity scroll compressor adapts to load and eliminates compressor cycling, greatly increasing compressor life
Lowest Total Cost of Ownership
  • Designed for higher return air temperature to maximize cooling capacity
  • Only front and back access required, resulting in minimized installation and service time
  • Variable capacity scroll compressor and variable speed EC fans operate efficiently to reduce energy consumption
Ideally Suited For
  • Small to medium-sized data centers cold/hot aisle configurations
  • Heat density up to 10 kW/rack without containment
  • Raised and non-raised floors
  • Rooms with a low ceiling where air cannot be ducted
  • Spot cooling in large data centers

Features:

  • Features variable speed EC plug fans and variable capacity scroll compressor
  • Enlarged range available from 10 to 60 kW
  • Efficient operation with the iCOMTM Control. The large graphic display allows easy navigation and clear data display
  • Includes a 300 mm space saving frame
  • Thermal management and humidity control
  • Installs within the row of racks
  • Low energy consumption